Designing electronics is tough.
Designing electronics that keep people alive is a whole different
ballgame. In the consumer world, if a phone glitches, you just restart
it. In the world of Medical Devices Development, a glitch can actually hurt someone.
The FDA and European regulators are extremely strict for a reason. Yet, every year, we see recalls and redesigns because of fundamental safety oversights. It isn't always because the idea was bad; usually, it’s because the execution missed a tiny, critical detail.
Here are the five most common safety failures that engineers see in the lab.
1. Electrical Shock Hazards (Leakage Current)
This is the big one. Electronics run on electricity, and the human body conducts electricity very well. If the internal power isn't properly isolated from the patient, you get leakage current. For a healthy person, a tiny shock might be annoying. For a patient with a catheter in their heart, a few microamps can be fatal. Meeting IEC 60601 standards for isolation is non-negotiable. It requires specific spacing on the circuit board and robust insulation that many inexperienced designers overlook.
2. Thermal Burns
Electronics generate heat. As devices get smaller and faster, that heat has nowhere to go. If a wearable sensor or a handheld surgical tool gets too hot, it can burn the patient’s skin. This often happens because the Medical Devices Development team focused on processor speed but forgot about heat dissipation until the prototype was already built. Managing thermals isn't just about performance; it is a safety requirement.
3. Alarm Fatigue and Failure
Alarms are supposed to alert doctors to problems. But if a device beeps for every little thing, medical staff stop listening. This is called "alarm fatigue," and it causes missed emergencies. Worse is when an alarm fails to sound because of a software bug or a broken speaker. A robust design needs a fail-safe. If the main speaker breaks, is there a backup buzzer? If the software freezes, does a hardware watchdog trigger an alert?
4. Unpredictable Software Behavior
Software bugs in medical devices are scary. A "race condition" in the code might only happen once every 1,000 hours of operation, causing an infusion pump to stop or a monitor to freeze. This is why standard coding practices don't cut it. You need rigorous verification and validation processes (IEC 62304) to ensure the code does exactly what it is supposed to do, every single time.
5. Battery Management Failures
Portable medical devices are great until they shut off mid-procedure. A common failure isn't just the battery running out, but the device thinking it has 20% left when it really has 1%. Accurate fuel gauging is harder than it looks. If the power management circuit isn't calibrated perfectly, the device might die without warning.
How to Avoid These Traps
Fixing these issues after you have built the molds and printed the circuit boards is expensive. It can kill a startup's budget.
This is where experienced Medical Devices Consultants like Voler Systems prove their worth. They don't just build what you ask for; they look for these failure points before they happen. With decades of experience in Medical Devices Development, Voler Systems ensures that the analog front end is isolated, the code is solid, and the device meets strict safety standards like IEC 60601.